| Alternative NSN: 5905-00-643-7182 |
| Item Name: Resistor Assembly |
| CAGE Code : 13439 , 63743 |
| NIIN: 006437182 |
| FSC Name: 5905 Resistors |
| NCB Code: USA (00) |
| Manufacturers: federal pacific electric co , ward leonard electric company inc |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| N1015PC8 | federal pacific electric co | resistor assembly | Avl | |
| 16933-9ED33604 | ward leonard electric company inc | resistor assembly | Avl | |
| 16778-9-5 | ward leonard electric company inc | resistor assembly | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAPP | ELECTRICAL RESISTANCE | 0.250 OHMS |
| AAPQ | RESISTANCE TOLERANCE IN PERCENT | -10.0 TO 10.0 |
| ACZQ | RESISTOR POWER DISSIPATION RATING IN WATTS | 2025.0 |
| AJJW | COMPONENT QUANTITY | 2 |
| ALGC | MOUNTING CONFIGURATION | EIGHT 13/32 IN. DIA MTG HOLES LOCATED 4 HOLES ON EA SIDE |
| AQHK | COMPONENT CONTROLLING AGENCY | WARD LEONARD ELECTRIC CO |
| AQHL | COMPONENT NAME | FIXED RIBBON WOUND RESISTOR |
| AQHM | COMPONENT IDENTIFYING NUMBER | 16778.9 DRAWING NO. |
| ATWY | ASSEMBLY CONSTRUCTION METHOD | MOUNTED ON PLATE AND STACKED W/THROUGH BOLT |
| ATYM | COMPONENT RELATIONSHIP | NOT MATCHED |
| AXGY | MOUNTING METHOD | BRACKET |