| Alternative NSN: 5915-00-393-1813 |
| Item Name: Filter Radio Freque |
| CAGE Code : 82423 , 13050 |
| NIIN: 003931813 |
| FSC Name: 5915 Filters and Networks |
| NCB Code: USA (00) |
| Manufacturers: kleinschmidt inc , spectrum control inc |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 20210 | kleinschmidt inc | filter radio freque | Avl | |
| 5004-3041A | spectrum control inc | filter radio freque | Avl | |
| 365-20210 | spectrum control inc | filter radio freque | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| ADAQ | BODY LENGTH | 1.937 INCHES MINIMUM AND 2.063 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 0.937 INCHES MINIMUM AND 1.124 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 1.938 INCHES MINIMUM AND 2.062 INCHES MAXIMUM |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.345 INCHES MINIMUM AND 2.405 INCHES MAXIMUM |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AKNA | INCLOSURE TYPE | ENCASED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 UNTHREADED HOLE |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB,SOLDER LUG INPUT 1ST FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB,SOLDER LUG OUTPUT 2ND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 400.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 400.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 400.0 VOLTS AT SEA LEVEL |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |