| Alternative NSN: 5915-01-356-5769 |
| Item Name: Filter Radio Freque |
| CAGE Code : 53733 , 82577 , 13058 |
| NIIN: 013565769 |
| FSC Name: 5915 Filters and Networks |
| NCB Code: USA (01) |
| Manufacturers: filtronetics inc , raytheon company , sora power inc |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 8655413-001 | filtronetics inc | filter radio freque | Avl | |
| 8655413-001 | raytheon company | filter radio freque | Avl | |
| 5033010 | raytheon company | filter radio freque | Avl | |
| 8655413-001 | sora power inc | filter radio freque | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABKW | OVERALL HEIGHT | 5.700 INCHES NOMINAL |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.1 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.25 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 17.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| ADAT | BODY WIDTH | 5.500 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 6.250 INCHES NOMINAL |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.1 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.1 6TH RADIO INTERFERENCE 6TH FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 4.8 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 7.3 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 15.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
| CTJS | UNPACKAGED UNIT WEIGHT | 14.500 POUNDS NOMINAL |
| FEAT | SPECIAL FEATURES | SEVENTY-FOUR FILTERED FUNCTIONS |
| ADAQ | BODY LENGTH | 5.500 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 4.600 INCHES MAXIMUM |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.225 INCHES NOMINAL |
| AFGA | OPERATING TEMP RANGE | -55.0 TO 85.0 DEG CELSIUS |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR,RECEPTACLE INPUT 1ST FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 CONNECTOR,RECEPTACLE OUTPUT 2ND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 23.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 29.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 41.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 80.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| CQRG | BODY MATERIAL | ALUMINUM |
| CRST | BODY SURFACE TREATMENT | TIN |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
Before You Go, You Should Consider Looking at Our NSN Parts Catalog. and Remember, ASAP Sourcing Solutions Has Some of the Fastest and Most Competitive Quotes On the Market.