| Alternative NSN: 5915-01-391-2557 |
| Item Name: Filter Radio Freque |
| CAGE Code : 0CYY5 |
| NIIN: 013912557 |
| FSC Name: 5915 Filters and Networks |
| NCB Code: USA (01) |
| Manufacturers: emission control ltd |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| DT40 | emission control ltd | filter radio freque | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABTD | MOUNTING SLOT WIDTH | 0.375 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 12.125 INCHES NOMINAL |
| ADAT | BODY WIDTH | 4.250 INCHES NOMINAL |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 40.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 40.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 THREADED STUD INPUT 1ST FUNCTION |
| CQRG | BODY MATERIAL | METAL |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 40.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| ABHP | OVERALL LENGTH | 12.750 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 2.750 INCHES NOMINAL |
| AFGA | OPERATING TEMP RANGE | -550.0 TO 85.0 DEG CELSIUS |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOT |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 THREADED STUD GROUND 3RD FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 THREADED STUD OUTPUT 2ND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |