| Alternative NSN: 5925-00-853-6198 |
| Item Name: Circuit Breaker |
| CAGE Code : 77342 , 79405 |
| NIIN: 008536198 |
| FSC Name: 5925 Circuit Breakers |
| NCB Code: USA (00) |
| Manufacturers: tyco electronics corporation , wood electric operations potter and brumfield |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 2135C | tyco electronics corporation | circuit breaker | Avl | |
| 501-235-103 | tyco electronics corporation | circuit breaker | Avl | |
| 107-235-104 | wood electric operations potter and brumfield | circuit breaker | Avl | |
| 501-235-103 | wood electric operations potter and brumfield | circuit breaker | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABXD | BUSHING LENGTH | 0.250 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 1.094 INCHES NOMINAL |
| ADAT | BODY WIDTH | 0.750 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 1 |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 SINGLE LOCATION |
| CQJX | NOMINAL THREAD SIZE | 0.469 INCHES |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
| THSD | THREAD SERIES DESIGNATOR | UNS |
| AAQL | BODY STYLE | SINGLE POLE TYPE |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.704 INCHES NOMINAL |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.812 INCHES NOMINAL |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 35.0 AMPERES AC AND 35.0 AMPERES DC SINGLE LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC AND 32.0 DC SINGLE LOCATION |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3500.0 AC AND 6000.0 DC SINGLE LOCATION |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
| CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 15.000 MINIMUM AT 200 PCT AND 55.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | SHOCKPROOF AND VIBRATIONPROOF |
| CTJS | UNPACKAGED UNIT WEIGHT | 2.000 OUNCES NOMINAL |
| CWJK | CASE MATERIAL | PLASTIC |
| FREQ | FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB W/SCREW |