| Alternative NSN: 5925-00-866-2960 |
| Item Name: Circuit Breaker |
| CAGE Code : 30598 , 98571 , 77342 , 79405 |
| NIIN: 008662960 |
| FSC Name: 5925 Circuit Breakers |
| NCB Code: USA (00) |
| Manufacturers: compunetics inc , teledyne controls llc , tyco electronics corporation , wood electric operations potter and brumfield |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 13-0550-0010 | compunetics inc | circuit breaker | Avl | |
| 830823-2 | teledyne controls llc | circuit breaker | Avl | |
| 842-201-101 | tyco electronics corporation | circuit breaker | Avl | |
| W23X1A1G-1 | tyco electronics corporation | circuit breaker | Avl | |
| 111-201-101 | wood electric operations potter and brumfield | circuit breaker | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | SINGLE POLE TYPE |
| ADAQ | BODY LENGTH | 1.375 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 0.687 INCHES MAXIMUM |
| AKPX | POLE QUANTITY | 1 |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.0 AMPERES AC AND 1.0 AMPERES DC SINGLE LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC AND 32.0 DC SINGLE LOCATION |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 100.0 AC AND 150.0 DC SINGLE LOCATION |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CWJK | CASE MATERIAL | PLASTIC |
| FREQ | FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |
| TEST | TEST DATA DOCUMENT | 98571-830823 DRAWING THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC. EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB W/SCREW |
| ABXD | BUSHING LENGTH | 0.365 INCHES MINIMUM AND 0.385 INCHES MAXIMUM |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.010 INCHES MINIMUM AND 1.030 INCHES MAXIMUM |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.035 INCHES MAXIMUM |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
| CMLP | THREAD QUANTITY PER INCH | 24 |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 135.0 SINGLE LOCATION |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
| CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.500 MINIMUM AT 200 PCT AND 1.800 MAXIMUM AT 200 PCT SINGLE LOCATION |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | SHOCK RESISTANT AND VIBRATION RESISTANT |
| THSD | THREAD SERIES DESIGNATOR | UNF |