| Alternative NSN: 5925-01-523-1916 |
| Item Name: Circuit Breaker |
| CAGE Code : 9Y580 , 06402 |
| NIIN: 015231916 |
| FSC Name: 5925 Circuit Breakers |
| NCB Code: USA (01) |
| Manufacturers: edo corporation , oakland industries ltd |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 124206 | edo corporation | circuit breaker | Avl | |
| 583-G111-K1M1-A1S1U-2A | oakland industries ltd | circuit breaker | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| ADAU | BODY HEIGHT | 38.0 MILLIMETERS NOMINAL |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS PROOF AND SHOCKPROOF AND VIBRATIONPROOF |
| CQJX | NOMINAL THREAD SIZE | 12.0 MILLIMETERS |
| AGAV | III END ITEM IDENTIFICATION | ALOFTS SONAR SYSTEM, MODEL 980 (V1) |
| AKPX | POLE QUANTITY | 3 |
| FEAT | SPECIAL FEATURES | BLACK PUSH BUTTON |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 2.0 AMPERES AC AND 2.0 AMPERES DC ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
| AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
| FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
| ADAT | BODY WIDTH | 45.0 MILLIMETERS NOMINAL |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 200.0 AC AND 28.0 DC ALL LOCATIONS |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 12.8 MILLIMETERS NOMINAL |
| ABXD | BUSHING LENGTH | 6.5 MILLIMETERS NOMINAL |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH BUTTON |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 SCREW |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC AND 6000.0 DC ALL LOCATIONS |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CQQR | THREAD PITCH IN MILLIMETERS | 1.25 |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
| ADAQ | BODY LENGTH | 19.5 MILLIMETERS NOMINAL |
| ADTV | CASE MATERIAL | PLASTIC |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| THSD | THREAD SERIES DESIGNATOR | ISO M |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 15.0 MILLIMETERS NOMINAL |
Before You Go, You Should Consider Looking at Our NSN Parts Catalog. and Remember, ASAP Sourcing Solutions Has Some of the Fastest and Most Competitive Quotes On the Market.