| Item Name: Relay Electromagnet |
| CAGE Code : 48313 , 99699 , 07031 |
| NIIN: 001428661 |
| FSC Name: 5945 Relays and Solenoids |
| NCB Code: USA (00) |
| Manufacturers: bc systems inc , dri relays inc , tempo instrument inc |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 94392 | bc systems inc | relay electromagnet | Avl | |
| G11-105-3003 | dri relays inc | relay electromagnet | Avl | |
| 94392 | tempo instrument inc | relay electromagnet | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
| AAJF | THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |
| ABHP | OVERALL LENGTH | 1.300 INCHES MAXIMUM |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| ABKW | OVERALL HEIGHT | 1.830 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 0.913 INCHES MAXIMUM |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AKDX | WINDING QUANTITY | 1 |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| APCN | COIL QUANTITY | 1 |
| APNA | WINDING DC RESISTANCE RATING | 300.0 OHMS NOMINAL SINGLE WINDING |
| APNP | DUTY TYPE | CONTINUOUS |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD SINGLE MOUNTING FACILITY |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CBME | CUBIC MEASURE | 2.172 CUBIC INCHES |
| CMLP | THREAD QUANTITY PER INCH | 40 SINGLE MOUNTING FACILITY |
| CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE MOUNTING FACILITY |
| CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
| CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 11.0 MILLIAMPERES DC SINGLE WINDING |
| CRXH | TIME DELAY | 0.02 SECONDS MAXIMUM FIXED OPERATE TIME |
| CRXH | TIME DELAY | 0.05 SECONDS MAXIMUM FIXED RELEASE TIME |
| CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES DC RESISTIVE LOAD |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
| THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
| TTQY | TERMINAL TYPE AND QUANTITY | 5 WIRE HOOK ALL FUNCTIONS |