| Alternative NSN: 5945-00-828-6498 |
| Item Name: Relay Electromagnet |
| CAGE Code : 73949 , H0212 , 58657 |
| NIIN: 008286498 |
| FSC Name: 5945 Relays and Solenoids |
| NCB Code: USA (00) |
| Manufacturers: guardian electric manufacturing co , koninklijke fabriek inventum b v , leach international corporation |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| A410-159604-02 | guardian electric manufacturing co | relay electromagnet | Avl | |
| 7S234513 | koninklijke fabriek inventum b v | relay electromagnet | Avl | |
| 9280 | leach international corporation | relay electromagnet | Avl | |
| 9274-6667 | leach international corporation | relay electromagnet | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABHP | OVERALL LENGTH | 3.000 INCHES MAXIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.625 INCHES NOMINAL FIRST MOUNTING FACILITY |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.250 INCHES NOMINAL FIRST MOUNTING FACILITY |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.250 INCHES NOMINAL SECOND MOUNTING FACILITY |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.173 INCHES NOMINAL FIRST MOUNTING FACILITY |
| AJSS | FREQUENCY IN HERTZ | 400.0 NOMINAL |
| AKDX | WINDING QUANTITY | 1 |
| APCN | COIL QUANTITY | 1 |
| APNQ | ARC QUENCHING METHOD | AIR |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE SECOND MOUNTING FACILITY |
| CBME | CUBIC MEASURE | 18.630 CUBIC INCHES |
| CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 100.0 MILLIAMPERES AC SINGLE WINDING |
| CRXH | TIME DELAY | 0.025 SECONDS MAXIMUM FIXED OPERATE TIME |
| CRXH | TIME DELAY | 0.05 SECONDS MAXIMUM FIXED RELEASE TIME |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC LAMP LOAD AND 3.0 AMPERES DC LAMP LOAD |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| TEST | TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTIN |
| ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS24568 GOVERNMENT STANDARD |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.625 INCHES NOMINAL SECOND MOUNTING FACILITY |
| ABKW | OVERALL HEIGHT | 2.700 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 2.300 INCHES MAXIMUM |
| ADTV | CASE MATERIAL | METAL |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.173 INCHES NOMINAL SECOND MOUNTING FACILITY |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| APNP | DUTY TYPE | CONTINUOUS |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE FIRST MOUNTING FACILITY |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR FIRST MOUNTING FACILITY |
| CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SECOND MOUNTING FACILITY |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC INDUCTIVE LOAD AND 10.0 AMPERES DC INDUCTIVE LOAD |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 6.0 AMPERES AC MOTOR LOAD AND 6.0 AMPERES DC MOTOR LOAD |
| TTQY | TERMINAL TYPE AND QUANTITY | 14 SCREW ALL FUNCTIONS |
Before You Go, You Should Consider Looking at Our NSN Parts Catalog. and Remember, ASAP Sourcing Solutions Has Some of the Fastest and Most Competitive Quotes On the Market.
Request for Quote