| Alternative NSN: 5950-00-152-8062 |
| Item Name: Transformer Power |
| CAGE Code : 11447 , 15634 , 72964 , 54401 , 80223 |
| NIIN: 001528062 |
| FSC Name: 5950 Coils and Transformers |
| NCB Code: USA (00) |
| Manufacturers: l 3 communications corporation , magnetika inc , robert m hadley company inc , transformer engineering llc , united transformer corp |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 2185668-1 | l 3 communications corporation | transformer power | Avl | |
| PA7194 | magnetika inc | transformer power | Avl | |
| 15301 | robert m hadley company inc | transformer power | Avl | |
| TE11982 | transformer engineering llc | transformer power | Avl | |
| PA7194 | united transformer corp | transformer power | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.630 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABTB | MOUNTING HOLE DIAMETER | 0.156 INCHES NOMINAL SINGLE GROUP |
| ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 2.380 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 2.000 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 2.430 INCHES MAXIMUM |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
| CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 111.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 113.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 58.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| TTQY | TERMINAL TYPE AND QUANTITY | 7 TAB,SOLDER LUG |