| Alternative NSN: 5950-00-899-7541 |
| Item Name: Transformer Power |
| CAGE Code : 72149 , 73386 , 10001 |
| NIIN: 008997541 |
| FSC Name: 5950 Coils and Transformers |
| NCB Code: USA (00) |
| Manufacturers: electronic transformer corp , freed transformer company , navair and navsea managed |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| S35710 | electronic transformer corp | transformer power | Avl | |
| 41308 | freed transformer company | transformer power | Avl | |
| 1676764 | navair and navsea managed | transformer power | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | 2.343 INCHES NOMINAL |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.062 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABMK | OVERALL WIDTH | 1.593 INCHES NOMINAL |
| ABTB | MOUNTING HOLE DIAMETER | 0.187 INCHES NOMINAL SINGLE GROUP |
| ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| ADAU | BODY HEIGHT | 2.312 INCHES NOMINAL |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED WITH OIL |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
| CBBL | FEATURES PROVIDED | COLOR CODED LEAD |
| CRBZ | WINDING OPERATING CURRENT | 12.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 100.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 100.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 25.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 25.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| TTQY | TERMINAL TYPE AND QUANTITY | 11 WIRE LEAD |