| Alternative NSN: 5950-01-274-9190 |
| Item Name: Transformer Pulse |
| CAGE Code : 13058 |
| NIIN: 012749190 |
| FSC Name: 5950 Coils and Transformers |
| NCB Code: USA (01) |
| Manufacturers: sora power inc |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| TP1000 | sora power inc | transformer pulse | Avl | |
| 230033-1 | sora power inc | transformer pulse | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | 10.000 INCHES NOMINAL |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.300 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 8.100 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKW | OVERALL HEIGHT | 8.710 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 8.720 INCHES NOMINAL |
| ACZN | PULSE REPETITION RATE | 1250.0 HERTZ SINGLE COMPONENT |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 6 SINGLE GROUP |
| AXGY | MOUNTING METHOD | CAPTIVE NUT SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 20.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| CWJS | WINDING OPERATING VOLTAGE | 10.00 DC KILOVOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 8.00 AC KILOVOLTS NOMINAL SINGLE COMPONENT SINGLE WINDING |
| FEAT | SPECIAL FEATURES | ITEMS ARE BEING CODED AS CRITICAL TO INSURE SOURCE INSPECTION WILL BE PERFORMED AT THE POINT OF MANUFACTURE,PRIOR TO MATERIAL RECEIPT BY THE US NAVY OR OTHER DOD COMPONENTS. THESE ITEMS ARE PIECE PARTS OR END ITEMS IN SUPPORT OF VITAL MILI |
Before You Go, You Should Consider Looking at Our NSN Parts Catalog. and Remember, ASAP Sourcing Solutions Has Some of the Fastest and Most Competitive Quotes On the Market.