Upload| Part Number : RF00200 | NSN : 5915008247975 |
|
| Manufacturer : Ems Development Corporation | CAGE Code : 13619 | FSC Details : 5915 Filters and Networks |
| NIIN : 008247975 | INC Code : 00765 | Country : USA |
| NCB Code : 00 |
Thank You for Submitting Your RFQ for Part Number RF00200 by Ems Development Corporation
We always put our customers’ needs first, and we are always just a click or call away from assisting you throughout the purchasing process whenever you need it. Please do not hesitate to call our toll-free number +1-714-705-4780 for any inquiries about part number RF00200, or send us an email listing your needs, and we will get back to you as soon as possible. Whatever your requirements may be, we will not rest until we have fulfilled all your operational needs with highly competitive options.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5915-00-824-7975 Item PartTypeName: FILTER,RADIO FREQUENCY INTERFERE | 5915 | 008247975 | Y | |||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| Z3 | U | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| FA4098 | 2 | 9 | 5 | Z3 | BFRGL |
| MRC | Criteria | Characteristic |
|---|---|---|
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.3 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.3 3RD RADIO INTERFERENCE 3RD FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR,RECEPTACLE OUTPUT 2ND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 300.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| ADAT | BODY WIDTH | 1.938 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 2.719 INCHES NOMINAL |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.125 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 3.628 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 4.750 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.125 INCHES NOMINAL |
| AFGA | OPERATING TEMP RANGE | -40.0 TO 85.0 DEG CELSIUS |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.1 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.1 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.3 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 6TH RADIO INTERFERENCE 6TH FUNCTION |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
| AKNA | INCLOSURE TYPE | ENCASED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 WIRE HOOK OUTPUT 3RD FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 14 WIRE HOOK INPUT 1ST FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 300.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 300.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| CQJX | NOMINAL THREAD SIZE | 0.164 INCHES |