If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.
Upload| Part Number : 50957 | NSN : 5930010791775 |
|
| Manufacturer : Gems Sensors Inc | CAGE Code : 04034 | FSC Details : 5930 Switches |
| NIIN : 010791775 | INC Code : 37187 | Country : USA |
| NCB Code : 01 |
Thank You for Submitting Your RFQ for Part Number 50957 by Gems Sensors Inc
We always put our customers’ needs first, and we are always just a click or call away from assisting you throughout the purchasing process whenever you need it. Please do not hesitate to call our toll-free number +1-714-705-4780 for any inquiries about part number 50957, or send us an email listing your needs, and we will get back to you as soon as possible. Whatever your requirements may be, we will not rest until we have fulfilled all your operational needs with highly competitive options.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5930-01-079-1775 Item PartTypeName: SWITCH,LIQUID LEVEL | 5930 | 010791775 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| LS-50957 | 6 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABHP | OVERALL LENGTH | 14.188 INCHES NOMINAL |
| ABJP | POWER CABLE LENGTH | 24.000 INCHES MINIMUM AND 26.000 INCHES MAXIMUM |
| ACYN | AC VOLTAGE RATING | 120.0 VOLTS MAXIMUM 2ND OPERATING POWER RQMT |
| ACYN | AC VOLTAGE RATING | 240.0 VOLTS MAXIMUM 3RD OPERATING POWER RQMT |
| ACYN | AC VOLTAGE RATING | 30.0 VOLTS MAXIMUM 1ST OPERATING POWER RQMT |
| ACYR | DC VOLTAGE RATING | 153.0 VOLTS MAXIMUM 2ND OPERATING POWER RQMT |
| ACYR | DC VOLTAGE RATING | 333.0 VOLTS MAXIMUM 3RD OPERATING POWER RQMT |
| ACYR | DC VOLTAGE RATING | 40.0 VOLTS MAXIMUM 1ST OPERATING POWER RQMT |
| ACZB | FREQUENCY RATING | 60.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
| ACZB | FREQUENCY RATING | 60.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
| ACZB | FREQUENCY RATING | 60.0 HERTZ MAXIMUM 3RD OPERATING POWER RQMT |
| AFLW | ACTUATION METHOD | BUOYANCY |
| AGBD | ELECTRICAL CONNECTION TYPE | CABLE |
| ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
| APGW | CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.08 AMPERES RESISTIVE LOAD |
| APGY | VOLTAGE RATING AT MAXIMUM RATED CURRENT | 120.0 VOLTS |
| AWAE | FLOAT QUANTITY | 1 |
| AWTN | OPERATING TEMP RATING | 0.0 DEG FAHRENHEIT MINIMUM AND 300.0 DEG FAHRENHEIT MAXIMUM |
| AXGY | MOUNTING METHOD | FLANGE |
| BBJX | MOUNTING POSITION | VERTICAL |
| BJKC | MAXIMUM CURRENT RATING | 0.17 AMPERES RESISTIVE LOAD |
| BJKD | CONTACT ARRANGEMENT | SINGLE-POLE,DOUBLE THROW,NORMALLY OPEN |
| BJKG | RELAY | NOT INCLUDED |
| BJKH | LIQUID TYPE FOR WHICH DESIGNED | VARIOUS FUELS |
| BJKQ | TANK INSERTION LENGTH | 11.938 INCHES MINIMUM AND 12.062 INCHES MAXIMUM |
| FAAZ | PHASE | SINGLE 1ST OPERATING POWER RQMT |
| FAAZ | PHASE | SINGLE 2ND OPERATING POWER RQMT |
| FAAZ | PHASE | SINGLE 3RD OPERATING POWER RQMT |
Before You Go, You Should Consider Looking at Our NSN Parts Catalog. and Remember, ASAP Sourcing Solutions Has Some of the Fastest and Most Competitive Quotes On the Market.