If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.
Upload| Part Number : ETN-2742 | Alternate P/N : ETN2742 | NSN : 5925007277550 |
|
|
Manufacturer : I T E Imperial Corp | CAGE Code : 31955 |
| FSC Details : 5925 Circuit Breakers | NIIN : 007277550 | INC Code : 00136 |
| Country : USA | NCB Code : 00 |
Thank You for Submitting Your RFQ for Part Number ETN-2742 by I T E Imperial Corp
We always put our customers’ needs first, and we are always just a click or call away from assisting you throughout the purchasing process whenever you need it. Please do not hesitate to call our toll-free number +1-714-705-4780 for any inquiries about part number ETN-2742, or send us an email listing your needs, and we will get back to you as soon as possible. Whatever your requirements may be, we will not rest until we have fulfilled all your operational needs with highly competitive options.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-00-727-7550 Item PartTypeName: CIRCUIT BREAKER | 5925 | 007277550 | P | |||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | ||||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| ETN-2742 | 1 | 2 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
| ADAQ | BODY LENGTH | 6.500 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 3.875 INCHES NOMINAL |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.375 INCHES NOMINAL |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.190 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 3.312 INCHES NOMINAL |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC AND 50.0 AMPERES DC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 15000.0 AC AND 10000.0 DC ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
| CPRQ | RESET METHOD | MANUAL |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 300.000 MINIMUM AT 200 PCT AND 900.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
| CWJK | CASE MATERIAL | PLASTIC |
| FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
| ADAT | BODY WIDTH | 4.125 INCHES NOMINAL |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 3.938 INCHES NOMINAL |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.375 INCHES NOMINAL |
| AJEC | BOSS HEIGHT | 0.187 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 3 |
| CBBL | FEATURES PROVIDED | ADJUSTABLE TRIP RELEASE |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 500.0 AC AND 250.0 DC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS AND TIME DELAY ALL LOCATIONS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 140.0 ALL LOCATIONS |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| CPSF | ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS | 600.0 TO 700.0 AC AND 600.0 TO 700.0 DC ALL LOCATIONS |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 QUICK DISCONNECT,FEMALE |
Before You Go, You Should Consider Looking at Our NSN Parts Catalog. and Remember, ASAP Sourcing Solutions Has Some of the Fastest and Most Competitive Quotes On the Market.
Request for Quote