
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.
Upload| Part Number : APS-064 | Alternate P/N : APS064 | NSN : 5950004954663 |
|
|
Manufacturer : United Transformer Corp | CAGE Code : 80223 |
| FSC Details : 5950 Coils and Transformers | NIIN : 004954663 | INC Code : 32496 |
| Country : USA | NCB Code : 00 |
Thank You for Submitting Your RFQ for Part Number APS-064 by United Transformer Corp
We always put our customers’ needs first, and we are always just a click or call away from assisting you throughout the purchasing process whenever you need it. Please do not hesitate to call our toll-free number +1-714-705-4780 for any inquiries about part number APS-064, or send us an email listing your needs, and we will get back to you as soon as possible. Whatever your requirements may be, we will not rest until we have fulfilled all your operational needs with highly competitive options.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5950-00-495-4663 Item PartTypeName: TRANSFORMER,POWER | 5950 | 004954663 | 0 | P | A | |
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | A | 0 | |||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 890827 | 6 | 9 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.060 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.060 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.060 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENTTHREE PHASE TO THREE PHASE SINGLE COMPONENTTHREE PHASE TO THREE PHASE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 4.250 INCHES NOMINAL4.250 INCHES NOMINAL4.250 INCHES NOMINAL |
| ADAT | BODY WIDTH | 2.950 INCHES NOMINAL2.950 INCHES NOMINAL2.950 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 2.370 INCHES NOMINAL2.370 INCHES NOMINAL2.370 INCHES NOMINAL |
| AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
| AGAV | END ITEM IDENTIFICATION | WSD AIRCRAFT,PHANTOM F-4 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSEDFULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 8 SECONDARY SINGLE COMPONENT8 SECONDARY SINGLE COMPONENT8 SECONDARY SINGLE COMPONENT |
| CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP32 SINGLE GROUP32 SINGLE GROUP |
| CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 1.1 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 178.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 189.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 310.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
| CRMJ | WINDING POWER RATING | 22.0 WATTS SINGLE COMPONENT SINGLE PRIMARY |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| CWJS | WINDING OPERATING VOLTAGE | 17.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY188.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY17.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 31.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 31.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY17.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY31.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 46.90 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 46.90 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY17.90 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY46.90 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| FEAT | SPECIAL FEATURES | 5TH SECONDARY 10.5V 118 MA,6TH SEC 10.5V 275 MA,7TH SEC 71.0V 1.5A,8TH SEC 77.5V 1.68A WEAPON SYSTEM ESSENTIAL |
| THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| TTQY | TERMINAL TYPE AND QUANTITY | 27 PIN |
Before You Go, You Should Consider Looking at Our NSN Parts Catalog. and Remember, ASAP Sourcing Solutions Has Some of the Fastest and Most Competitive Quotes On the Market.
Request for Quote